Shanghai Jiashang Environmental Technology Co., LTD

With the product quality unlimited, service unlimited culture, and as the spirit of enterprise into the enterprise management

Manufacturer from China
Site Member
11 Years
Home / Products / On Site Sodium Hypochlorite Generation /

Auto on site sodium hypochlorite generator-CNJS-5000

Contact Now
Shanghai Jiashang Environmental Technology Co., LTD
City:shanghai
Province/State:shanghai
Country/Region:china
Contact Person:MrsSherry
Contact Now

Auto on site sodium hypochlorite generator-CNJS-5000

Ask Latest Price
Video Channel
Brand Name :JSSHG
Model Number :CNJS
Certification :ISO9001
Place of Origin :CHINA
MOQ :1set
Price :dollar
Payment Terms :T/T
Supply Ability :100 set per month
Delivery Time :4 weeks
Packaging Details :Wooden case
Titanium :Disinfection
Application :Water disinfection,waste water treatment plant,drinking water treatment,Water Storage
Salt consumption :3.5kg/kg Cl2
Capacity :1500g/h active chlorine
Power consumption :4.0kw per kg Cl2
Warranty :5 years for the electrode
Product name :brine electrolysis Sodium Hypochlorite generator
Naclo concentration :0.8%
Type :chemical sterilization,Module
Function :water treatment
Material :titanium
Concentration :0.7~0.9%(7000~9000ppm)
Usage :brine electrolysis
Name :Sodium hypochlorite generator
Available cl2 concentration :7-9g/L
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Why choose Jiashang Technology

Design strength, production quality, safety assurance, project performance

1,Technical strength

Auto on site sodium hypochlorite generator-CNJS-5000

2,Safety protection of system design

a. Safety of raw material storage

b. Main components are equipped with spare parts to ensure safe operation

c. Indoor hydrogen concentration detection

d. Inflow flow detection e. Water inlet pressure detection

f. Liquid level detection of electrolytic tube g. Electrode temperature detection

h. Electrolytic current detection i. Electrolytic voltage detection

j. Brine concentration detection k. Strong exhaust dilutes hydrogen

l. Wind pressure detection m. More accurate dosing and safer effluent

n. Dosing flow monitoring

p. The reserve of sodium hypochlorite can be increased according to the actual situation

3,Electrode structure of patented technology

Electrode plate: plate electrode. The anode and cathode base materials of the electrode are all made of pure titanium TA1 material. In the electrolysis process, the cathode is protected, while the anode is lost, so the anode surface must be protected by coating. The anode surface of jsshg brand generator electrode is coated with ruthenium and iridium oxide with particle fineness of 20 nm, which is treated by nanotechnology. The coating is divided into more than 18 times, and the coating thickness is 20 microns, which can ensure the long-term Stable service life.

4,Fully transparent electrolytic cell

The following figure:

Auto on site sodium hypochlorite generator-CNJS-5000

Our electrolyzer is the only fully transparent design in China, including flanges. When dilute brine is electrolyzed, the electrolytic state is clear at a glance. For electrolysis, the most important thing to pay attention to is whether the electrolytic cell is scaling and whether the electrode works in a safe state. The fully transparent electrolytic cell can visually see the actual situation, so as to better protect the electrolytic cell. The electrolyzer is equipped with liquid level protection, low temperature protection, high temperature protection, low current protection, ultra-high current protection, low voltage protection and ultra-high voltage protection. Once there is an abnormality, the system will send an alarm signal and stop working.

5,Energy saving electrolytic power supply

The following figure:

Auto on site sodium hypochlorite generator-CNJS-5000

Sodium hypochlorite generator uses high-frequency constant current electronic switching power supply as the electrolytic power supply. Due to the use of high-frequency rectification technology, the AC / DC conversion efficiency reaches more than 95%, the calorific value is very low, the operation is stable, and the volume is small, which is more than 20% higher than the electrical conversion efficiency of ordinary silicon rectifier (sodium hypochlorite generator GB 12176-90 requires current efficiency ≥ 72%).

6,Immediate hydrogen removal technology

a),LFL (Lower Flammable Limit of H2 ) : 4%

b),Dilution air to hydrogen ratio 100:1

c),The concentration of H2 diluted is 25% of LFL

Auto on site sodium hypochlorite generator-CNJS-5000

Schematic diagram of hydrogen removal

7,Salt dissolving system

PE salt dissolving tank of drinking water safety standard is adopted to ensure the safety of drinking water. Saturated salt water is mixed with soft water through salt water pump to reach 3% dilute salt water.

Salt dissolving device: use self-made high-efficiency salt dissolving device to achieve stable saturated salt water, without salt dissolving pump and agitator.

Automatic water inlet control: the brine tank is equipped with high and low liquid level controllers to automatically control the water level. When the low liquid level is reached, the water inlet solenoid valve is opened, and the system water inlet. When the high liquid level is reached, the water inlet solenoid valve is closed, a reminder signal is sent on the touch screen, and the water inlet is stopped.

8,Soft water system

Softener resin is installed in the water softener. This artificial ion exchange resin has soft mineral sodium, which can react with hard minerals such as calcium and magnesium dissolved in water. After ion exchange, calcium and magnesium ions are adsorbed on the resin in the water softener, and the outflow water becomes soft. Finally, after all resins are fully adsorbed with calcium and magnesium ions, they can no longer work, but need regeneration treatment, which includes backwashing, regeneration, replacement and fast flushing.

9,Dosing system

a,Dosing diagram (Two for use and one for standby)

Auto on site sodium hypochlorite generator-CNJS-5000

Schematic diagram of dosing system

b, Dosing pump brand

The standard configuration of dosing system is Italian brand: Seko metering pump

Customers can choose: German prompt metering pump, American Milton Roy metering pump.

Inquiry Cart 0