Ask Latest Price
Brand Name :CNJS
Model Number :CNJS-S
Certification :ISO9001
Place of Origin :CHINA
MOQ :1 SET
Price :NEGOTIATION
Payment Terms :L/C, T/T, Western Union
Supply Ability :100 SETS /month
Delivery Time :7-15 work days
Packaging Details :wooden case
Available chlorine :7.0-9.0 g / L
Power input :220V, 50Hz
Inlet water temperature :5-27℃
Inlet water pressure :0.2-0.4Mpa
Salt consumption :3.5kg/kg Cl2
Water consumption :125L/kg Cl2
Electrolytic liquid :2.5~3% weak brine
Content available CL :7000~9000ppm
Rated current :Determined according to the selected product model
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description


IS9001 Approval Sodium Hypochlorite Generator / Sodium Hypochlorite Electrolysis


Technical parameters:

Type

Av.CL2 Capacity
(g/h)

Flow Rate
(L/h)

Salt Consumption
(kg/d)

Water
Consumption
(m3/d)

Rated power
(kw )

Unite size
(L×W×H)
(mm)

CNJS-S-100

100

13

8.4

0.31

0.6

1200×800×1400

CNJS-S-200

200

25

16.8

0.6

1.2

1200×800×1400

CNJS-S-300

300

38

25.2

0.91

1.8

1200×800×1400

CNJS-S-400

400

50

33.6

1.2

2.4

1200×800×1400

CNJS-S-500

500

63

42

1.51

3

1200×800×1400


Note:System requirements with salt and water

Salt requirements:

Name

Request content( %)

(NaCl)

>99.3 %

(Fe)

<0.002%

(Ca Mg)

<0.023%

(Mn)

<0.00003%

(Pb)

<0.0007%

(Cu)

<0.0003%

(F)

<0.01%

Water requirements:
1)Operating water temperature:
The temperature between (18˚C-23˚C)is best. If do not use temperature regulation, please allow the temperature between (10˚C-27˚C),or a heating exchanger or chiller equipment to be used for adjust the water temperature.
2)Operating water pressure:
Minimum 0.2 MPa, Maximum 0.35 Mpa, if not in this scope, need to increase a he pressure or vacuum equipment
3)water quality requirements:
pH 6.5 to 8.5
hardness[in calcium carbonate] < 5 ppm (soft water equipment outlet)
COD(Mn) < 1.5 ppm
Fe < 0.2 ppm
Mn < 0.01 ppm
Ni < 5 ppm
F <2 ppm
Cu < 5 ppb



Product introduction:

Generation principle:

The revolutionary CNJS-S series sodium hypochlorite generator is a newly and for on-site product of NaClO equipment and use for all kinds of needed NaClO disinfected. Its working principle is :the sodium chloride solution under the certain voltage effect of the cell, a series of electrochemical reaction within the cell and the resulting solution is the NaClO solution. The main process can be simplified as follows:

IS9001 Approval Sodium Hypochlorite Generator / Sodium Hypochlorite Electrolysis
The electrode reaction:
anode:2Cl--2e→Cl2
cathode:2H++2e→H2
solution:2NaOH+Cl2→NaCl+NaClO+H2O

Work flow chart:


IS9001 Approval Sodium Hypochlorite Generator / Sodium Hypochlorite Electrolysis
Product components system

A,inlet water distribution system
Main components: water pressure gauge, water softener, soft water pump, water meter, salt tank, salt water pump and related piping and valves.

IS9001 Approval Sodium Hypochlorite Generator / Sodium Hypochlorite Electrolysis
B,The power control system:
Including control cabinet, rectifier and cable connection.

IS9001 Approval Sodium Hypochlorite Generator / Sodium Hypochlorite Electrolysis
IS9001 Approval Sodium Hypochlorite Generator / Sodium Hypochlorite Electrolysis
C,Storage and dosing system
Including electrolytic cell, NaClO tank, dosing pump, piping and valves.

IS9001 Approval Sodium Hypochlorite Generator / Sodium Hypochlorite Electrolysis


Advantage of on-site sodium hypochlorite generator

SAFETY:
Material safety: Salt, Water and Electricity as raw materials, no need for transportation of dangerous chemicals;
Process safety: No risk of chlorine leakage and reactor explosion, safety for operator;
Product safety: Product-0.8% NaCIO solution, has the advantage of stable and safety, cost effective in operation and no attenuation in storage.
ENERGY-SAVING:
Make use of electricity in the off-peak period to generate the NaCIO solution.
ENVIRONMENTAL PROTECTION:
Avoid of usage, transportation of dangerous chemical material.
High current efficiency ,few by-product, safe H2 ventilation.
ECONOMY:
JIASHANG equipment can largely reduce the operation cost compared to the bulk hypochlorite


TAG:

Sodium hypochlorite generator, On-site sodium hypochlorite

DETAILS:

IS9001 Approval Sodium Hypochlorite Generator / Sodium Hypochlorite Electrolysis


IS9001 Approval Sodium Hypochlorite Generator / Sodium Hypochlorite Electrolysis









































































China IS9001 Approval Sodium Hypochlorite Generator / Sodium Hypochlorite Electrolysis for sale

IS9001 Approval Sodium Hypochlorite Generator / Sodium Hypochlorite Electrolysis

Inquiry Cart 0